Energy Savings & ROI

Energy savings and return on investment

Turn Better Airflow into Lower Building Operating Costs.

MegaFan HVLS systems can reduce energy waste by returning trapped roof heat to the occupied zone, improving the distribution of conditioned air and operating only when the building requires airflow.

Use the interactive calculator to explore possible annual savings, then request a project-specific assessment using the real building, energy consumption, tariffs, operating hours and proposed fan system.

Where The Financial Opportunity Comes From
Reduce Waste Before Buying More Heating Or Cooling Capacity

In a high building, useful heating energy can collect close to the roof while the occupied working zone remains below its target temperature. During warmer periods, conditioned or fresh air can also be poorly distributed across a large space.

MegaFan systems focus on moving the air already being heated, cooled or supplied so that a larger proportion reaches the areas where it is actually required.

The financial case should then compare the energy or operating cost avoided with the electricity, maintenance and capital cost introduced by the proposed airflow system.

Winter

Winter Destratification

Return warm roof-level air towards the occupied zone so that less heater power or operating time may be required to maintain the target working temperature.

Summer

Summer Air Movement

Improve perceived comfort and help distribute conditioned or incoming air across occupied areas more effectively, subject to measurement and verification before changing HVAC settings.

Operation

Controls & Scheduling

Operate fans at the speed, time and location actually required rather than running every device continuously, helping reduce unnecessary operating hours.

Verification

Measure & Verify

Use energy bills, meter data, operating hours and temperature measurements to confirm whether the expected saving is being achieved after the system is installed.

Calculate net savings rather than relying on a headline percentage. Start with the heating, cooling or operating cost that could realistically be avoided, subtract fan electricity and other operating costs, then compare the result with the installed capital cost of the proposed system.
What The Percentages Mean In Money
Illustrative Gross Annual Savings At Different Energy-Spend Levels

The examples below show what 32%, 40% and 45% would represent against different levels of relevant annual heating spend. These are simple gross illustrations before fan electricity, project cost, maintenance and other adjustments.

Relevant Annual Heating Spend 32% Gross Illustration 40% Gross Illustration 45% Gross Illustration
£10,000 £3,200 £4,000 £4,500
£25,000 £8,000 £10,000 £11,250
£50,000 £16,000 £20,000 £22,500
£100,000 £32,000 £40,000 £45,000
£250,000 £80,000 £100,000 £112,500
These figures are illustrations, not promised MegaFan savings. The percentage should only be applied to the energy spend genuinely affected by the proposed airflow system. A real ROI assessment should account for the building survey, heating system, operating hours, fan electricity, installation cost, maintenance and measured or suitably supported savings assumptions.
ROI Calculator

Estimate Your Potential Energy Savings & Payback

Enter the figures for your proposed project to calculate an illustrative annual saving, fan running cost and simple return on investment.

£
Enter only the energy spend affected by the proposed fan project.
%
Use a project-specific assumption supported by the building assessment.
Include all fans expected to operate in the assessed mode.
W
300 W is an editable example and should be replaced with the expected project figure.
hrs
Use the expected annual operating schedule after controls and occupancy are considered.
£ /kWh
Replace the example with your actual electricity tariff.
£
Include fans, controls, installation, access equipment, electrical work and other relevant project costs.
Planning estimate only. This calculator provides a simple annual illustration. It does not include finance costs, inflation, tariff changes, tax, maintenance, downtime, weather normalisation, residual value or every project-specific cost and benefit.
Illustrative Annual Result

Your Planning Estimate

Gross Avoided Energy Cost £20,000 Annual spend multiplied by the assumed saving percentage.
Fan Electricity Cost £150 Fan quantity × power × annual hours × electricity price.
Simple Payback 1.0 years Installed project cost divided by estimated annual net saving.
Average Monthly Net Saving £1,654 Estimated annual net saving divided by twelve.
Five-Year Simple Net Benefit £79,250 Five years of net savings minus the initial project cost.
£50,000 × 40% = £20,000 gross saving. 1 fan × 0.300 kW × 2,000 hours × £0.25/kWh = £150 fan electricity. Estimated net annual saving: £19,850.
Controls Protect The Saving
Do Not Waste Electricity By Running Fans Harder Or Longer Than Required

A fan system should not simply be installed and assumed to operate at maximum speed throughout every occupied hour. The airflow requirement can change with temperature, season, occupancy, operating schedules and the part of the building being used.

Appropriate controls allow compatible MegaFan systems to operate at the speed, time and location required. Depending on the selected products, the control strategy can range from straightforward manual speed control through to centralised or automated multi-device operation.

The ROI principle is simple: if the financial case assumes that airflow reduces heating demand, improves distribution or avoids other operating costs, unnecessary fan electricity must also be controlled. Net savings should be calculated after fan electricity and other operating costs — not from the avoided energy figure alone.
01 / Speed

Individual Fan-Speed Control

Adjust compatible fans to the airflow actually required rather than assuming full-speed operation is necessary at all times.

02 / Temperature

High & Low Temperature Monitoring

Temperature monitoring can support automated operation around conditions at different heights within a building, particularly where winter destratification is being controlled.

03 / Seasonal

Summer & Winter Modes

Compatible automated systems can use different operating strategies for summer air movement and lower-speed winter destratification rather than relying on one fixed fan setting all year.

04 / Scheduling

Weekly Occupancy Schedules

Scheduled operation can match airflow to working periods so equipment is not unnecessarily operated during predictable unoccupied periods.

05 / Zones

Zone-Based Operation

Where the final system supports it, separate building areas can be controlled around their own occupancy and airflow requirements rather than treating the whole facility as one zone.

06 / Integration

BMS & Modbus Integration

Compatible control systems can interface with wider building-management strategies, allowing fan operation to form part of coordinated temperature and operating controls.

07 / Safety

Fire-Alarm Shutdown Input

Supported controller configurations can include a fire-alarm shutdown input so fan operation can be incorporated into the building's required control and safety strategy.

08 / Monitoring

Alarm & Fault Reporting

Monitoring and fault reporting help identify system issues that could otherwise leave equipment operating incorrectly or prevent the intended airflow strategy from being delivered.

Not every MegaFan product supports every control function. The available controller, sensors, automation, communications and integration features must be confirmed for the selected fan products and final system design. Controls can help reduce unnecessary operating hours and manage the intended airflow strategy, but they do not by themselves guarantee a particular energy saving or ROI.

Any Questions just Contact Us

Frequently Asked Questions

Energy savings from HVLS fans depend on the building, heating or cooling system, operating hours, controls, energy tariffs and how effectively air is currently being distributed. The potential benefit should therefore be assessed against the actual energy use affected by the proposed system, rather than applying a headline percentage to the whole site.

 

MegaFan systems can support lower winter heating demand through destratification, improve the distribution of conditioned air, and reduce unnecessary fan operating hours through suitable controls and scheduling. The final ROI should compare the verified or reasonably supported cost saving against fan electricity, maintenance and the installed project cost.

 

These FAQs explain how energy savings are calculated, what affects the potential payback period, how the University of Liverpool modelling should be interpreted, and why measurement and verification are important before claiming a final saving.

How much can an HVLS fan save?

Savings depend on the building, heating or cooling system, temperature gradient, energy prices, operating hours and controls. The University of Liverpool model indicated approximately 32% heater-power saving at a 12.5 metre apex and 40% to 45% for the 15 to 20 metre cases at an outside temperature of 4°C. These were modelled results, not guaranteed savings for every site.

It used Computational Fluid Dynamics to model airflow and heat transfer in a generic 30 metre by 30 metre warehouse zone. Heater power was adjusted to maintain an average temperature of 16°C at 1.5 metres above the floor with the HVLS fan on and off.

No. They were estimates from a computational model. The report explicitly noted assumptions and recommended validation against measurements from a real warehouse. The results must therefore be treated as evidence of potential rather than a guaranteed outcome.

Warm air naturally rises and can collect near the roof. An HVLS fan moves that air towards the occupied zone and mixes the temperature layers. When more of the existing heat reaches floor level, the heating system may need less power or fewer operating hours to maintain the target temperature.

High buildings contain a larger volume above the occupied zone and can develop a greater floor-to-ceiling temperature difference. The Liverpool model found the largest percentage savings in the 15 to 20 metre apex cases, while the 12.5 metre model still showed approximately 32%.

Air movement can improve perceived comfort and help distribute conditioned air. This may allow changes to air-conditioning settings or operating hours after the effect has been verified. The saving is highly site-specific and should not be assumed without an assessment.

Compare energy use before and after installation over representative periods, while accounting for weather, operating hours, production levels, occupancy and tariff changes. Sub-metering and recorded high-level and low-level temperatures can improve confidence in the result.